Description
The type A Double light fixture has a primary LED and a secondary LED. In the event of a fault on the main circuit, the secondary LED will illuminate. Switching is done with the help of the monitoring system.
It is used to mark air obstacles such as towers, buildings, antennas.
Designed and manufactured in Romania.
Photometric specifications
Light source: high intensity OSRAM LEDs
Light intensity: Type A Double: over 10 cd
The minimum luminance requirements for the low-intensity type A Double light fixture is:
Between 2 ° and 10 ° the minimum intensity is 10cd according to ICAO Annex 14 Volume I
Technical specifications
The casing is made of powder coated aluminium.
The diffuser is made of clear polycarbonate.
The light beacon is a attached to a pipe with a diameter of 32-65mm.
The light beacon can be equipped with a twilight switch, a monitoring system or a photo-voltaic panel.
Electrical specifications
Electrical safety class I
Power supply 110-230V AC, 50/60Hz
12V DC,24V DC sau 48V DC
Power consumption 1,5 W
Operating environment
Rated operating temperature from -20 °C up to +40 °C.
The ingress protection rating is IP 66.
The impact protection rating is IK 10.
Dimension specifications
70 x 140 mm
Weight 0,9kg